PESTICIDE & HERBICIDE ANALYSIS KITS CATALOG INFORMATION
 
Catalog # Description
0352-0002 Carbamate Pesticides Analysis Kit, 23+ Compounds
0840250 Carbamate Column, C8, expanded resolution, 4.0 × 250 mm & 1700-0063 Carbamate Test Mixture, 2.5 µg/mL, 1.5 mL
18ECG001 Guard Cartridge Holder with 3 guard cartridges
CB130 Hydrolysis Reagent for Carbamate analysis 0.05 M
CB910 o-Phthalaldehyde (OPA) Diluent for Carbamate analysis
O120 o-Phthalaldehyde, 5 g
3700-2000 Thiofluor™
1700-0132 ChlorAC Buffer

 

Catalog # Description
0352-0003 Carbamate Pesticides Analysis Kit, for EPA Method 531.1:
1846250 Carbamate Column, C18, high resolution/capacity, 4.6 × 250 mm & 1700-0063 Carbamate Test Mixture, 2.5 µg/mL, 1.5 mL
18ECG001 Guard Cartridge Holder with 3 guard cartridges
CB130 Hydrolysis Reagent for Carbamate analysis 0.05 M
CB910 o-Phthalaldehyde (OPA) Diluent for Carbamate analysis
O120 o-Phthalaldehyde, 5 g
3700-2000 Thiofluor™
1700-0132 ChlorAC Buffer

 

Catalog # Description
0352-0009 Carbamate Pesticides Analysis Kit, for EPA Method 531.2:
1846250 Carbamate Column, C18, high resolution/capacity, 4.6 × 250 mm & 1700-0063 Carbamate Test Mixture, 2.5 µg/mL, 1.5 mL
18ECG001 Guard Cartridge Holder with 3 guard cartridges
CB130.2 Hydrolysis Reagent for Carbamate analysis 0.075 M
CB910 o-Phthalaldehyde (OPA) Diluent for Carbamate analysis
O120 o-Phthalaldehyde, 5 g
3700-2000 Thiofluor™
1700-0132 ChlorAC Buffer

 

Catalog # Description
0352-0004 Carbamate Pesticides Analysis Kit, for AOAC Method 985.23:
1846150 Carbamate Column, C18, rapid analysis, 4.6 × 150 mm & 1700-0063 Carbamate Test Mixture, 2.5 µg/mL, 1.5 mL
18ECG001 Guard Cartridge Holder with 3 guard cartridges
CB130 Hydrolysis Reagent for Carbamate analysis 0.05 M
CB910 o-Phthalaldehyde (OPA) Diluent for Carbamate analysis
O120 o-Phthalaldehyde, 5 g
3700-2000 Thiofluor™
1700-0132 ChlorAC Buffer

 

Catalog # Description
0352-0010 Glyphosate Herbicide Analysis Kit, for EPA Method 547, AOAC Method 991.08:
1954150 Cation-exchange Column for Glyphosate analysis, 4 × 150 mm & 1700-0080 Glyphosate test mixture, 2.5 µg/mL, 1.5 mL
1700-3102 Cation-exchange GARD™ Assembly: Includes holder and 2 replaceable GARD™
K200 Glyphosate Potassium Phosphate Eluant
RG019 Glyphosate Column Regenerant
GA104 o-Phthalaldehyde (OPA) Diluent for Glyphosate analysis
GA116 Hypochlorite Diluent for Glyphosate analysis
O120 o-Phthalaldehyde, 5 g
3700-2000 Thiofluor™
1700-0140 RESTORE™, removes metal ions from Glyphosate column and guard