PINNACLE PCX SPECIFICATIONS
• Dimensions: 21.25” H x 10.5” W x
18.25” D
• Weight: 60 lbs – Duplex
• Electrical: 100-120V, 50/50 Hz, 1.7 A,
200 W or 200-240 V, 50/60 Hz, 0.8 A,
200 W
• Mains voltage ± 10% of nominal
• Installation (over voltage) category II,
pollution degree 2
• Indoor use only
• Environmental: Altitude up to 6500 ft
• Ambient Temperature 2°- 40° C
• Relative humidity up to 80% at 31°C.
REAGENT PUMPS
• True pulse-free syringe pump
• Single piece ceramic barrel
• Completely inert flow path
• Maximum operating pressure 500 psi
• Programmable flow-rate
• Flow range: 50 µL to 1500 µL/minute
• Refill cycle of 60 seconds
• Automatic piston wash
• Automatic reagent flush cycle
• No check valves
CONTROL
• Computer controlled
• Windows PC with 98, 2000, NT, XP
• Serial RS232 connection or network
REACTOR
• Heated reactor for temperature from 5° C
above ambient to 130° C
• Easy replacement coil cartridges
• Range of reactor dwell volumes;
0.1 mL to 3mL
• Reaction coil withstands up to 42 bar
(600 psi) inlet pressure at 130° C
• Thermal safety switch limits temperature
to 150° C to prevent damage
• Fast response
SAFEGUARDS
• In-line check valve: Prevents reagent
back flow into the column when
HPLC pressure drops
• Replaceable filters prevent column
and reagent fouling
• Post-column system over pressure:
A pre-calibrated relief valve opens at
35 bar (500 psi) to prevent rupture of the
post-column reactor tubing in the event of
down-stream blockage
• Back-pressure regulator: Applies 7 bar
(100 psi) to the detector flow cell outlet
(waste) to prevent detector noise and
precipitation due to out-gassing or boiling
|
COLUMN HEATER AND REACTOR CONTROLLER
• Heater accepts up to 6 or 8 mm OD
(0.25 or 0.31 inch) x 50-250 mm
in length (column and guard)
• Programmable Temperature gradient
• Temperature holds within ± 0.4°C from
the set point. Could be set with 1° C
resolution from 5° C above ambient to
75° C
• Easy column access
INSTRUMENT PACKAGE AND FLOW PATH
• Advanced fluidics valve
management system
• Easy access to internal components
• Standard fittings
• Post-column pressure relief valves
• Side panels easily removed for service
• Integrated Reagent reservoir tray
• Corrosion proof pan and panels
DISPLAY
• Back lit LCD
• Real time temperature and
pressure display
• System Status icons
• Simple system control interface
GAS PRESSURE MANIFOLD AND REGULATOR
• Panel mount manifold
• Regulator maintains 0.3 bar (3-5 psi) on
reagent reservoirs with 3-5 bar
(45-75 psi) source pressure
• Safety Pressure-relief valve opens at 1
bar (14 psi)
• Manifold has two 1/4-28 fittings
• Gas lines with anti-syphon valves
PRESSURIZED REAGENT RESERVOIR
• One liter capacity (2 and 5 L reservoirs
available)
• Maintained under inert gas pressure to
inhibit oxidation of sensitive reagents
• Valve built into reservoir cap permits
sparging during reagent preparation
• Reagent reservoirs fitted with 3.1 mm
(1/8”) OD (oxygen-impermeable) SARAN
tubing for oxygen-sensitive reagents
|