Overview
GPC QUATTRO
Parallel Processing for GPC Sample Clean-up
Gel Permeation Chromatography is a well-known technology for the removal of fats, proteins, and other large bio-molecules from samples in order to prevent interference in the analysis of chlorinated hydrocarbon pesticides, PCBs, antibiotics, mycotoxins, polyaromatic hydrocarbons (PAH), and other semi-volatile compounds.
The GPC Quattro technology can be used for the clean-up of complex animal tissues, food products, and environmental samples. The high recoveries and concentrated samples are easily analyzed by GC, GC-MS, HPLC or LC-MS.
Ideally suited for high-throughput laboratories requiring reliability and reproducibility, the GPC Quattro is designed for 4x the productivity of a single column system. Engineered for robustness and low maintenance, the GPC Quattro provides the ease of use necessary for increased throughput and worry-free operations.
Feature Highlights
Feature Highlights
- 4 Columns for parallel processing or individual processing
- Touchscreen operation or PC software operation
- Run-time fail-safe feature – saves programming if interrupted
- Waste level sensors
- Reproducible high recoveries
- Small footprint
Parallel processing in four separately programmable
columns improves productivity by 400% at a fraction
of the cost of four 1-column systems
Specifications
Specifications
Dimensions
- Stand-alone system
- W x D x H; 65 x 45 x 48 cm: Without columns
Power Supply
- 88 – 245 V Wide Range Power Supply
Solvent Wetted Parts
- Stainless Steel
- Ceramics
- PTFE
GPC Pump
- 4 Individual preparative pumps
- 62 bar/900 psi Maximum pressure
- Dual-piston pumps
- Flow Rate: 1 – 40 mL/min
Injection
- 4 Manual injection and switching of injection valve
Sample Loop
- Standard is four 5.0 mL loops; others on request
Parameterization
- Flow Rate: 1 – 40 mL/min
- Forerun: 0 – 999 min
- Main Run: 0 – 999 min
- Tailings: 0 – 999 min
- Global minimum pressure in bar or psi
- Maximum pressure for each individual column in bar or psi
- Methods/Names assigned to each column
Display
- Touchscreen with color and graphic support and function keys
- Simulated alphanumeric input via touchscreen
- Integrated method management with input of new methods and names
- System activity via symbols
- Color-coded status of forerun, main run and tailings for each individual column
- Actual flow path and pressure highlighted in red
- Time bar showing elapsed run time
- Remaining run time via figures
- Actual and set maximum pressure for each column
- Errors by symbol (language independent) in the screen of the process engineering
- Chronological list of errors in clear text by pressing f2
Safety Features and Error Management
- High and low pressure shut-off
- Waste level sensor with shut-off
- Defined “load” and “inject” position with safety timer (calculates minimum time from flow rate and sample loop size for re-switching to “load” position)
- External columns and liquid strictly separated from electric compartment
- Easy access to pump housing from top by lifting electric compartment
- Password protected system setup
- In case of power failure timer values are stored in order to resume or stop process
- Reset of timers when run was aborted
- Manual switch for eluate valve for rinsing purpose in “load” position
- Air exhaust louver at rear panel
- Main switch to the right of the display
Upgrades
- Easy upgrading of general software by CF card
- Upgrade 1: Individual programming of each column
- Upgrade 2: Four waste level sensors
- Upgrade 3: Data and process visualization on PC via VNC viewer